sales1@unitedcontrolengg.com
GSTIN : 09AACCU4195M1ZP

ABB Switchgears

Unlock the advantages of our ABB Switchgears, the top-notch electrical equipment that is perfect for all your power distribution needs. As an experienced exporter, service provider, distributor, supplier, and trader with over 24.0 years of experience, we offer the best price for our immaculate range of ABB Switchgears. Our new release includes ABB Four Pole MCB /SB204M-C0.5, ABB Single Pole MCB /SB201M-C3, ABB Double Pole MCB /SB202M-C6, ABB Single Pole MCB /SB201M-C63, and ABB Triple Pole MCB /SB203M-C50.

Our gorgeous ABB Switchgears are designed to provide reliable and safe power distribution in various applications. With our ABB Switchgears, you can enjoy five advantages and features, including high-quality performance, easy installation, low maintenance, durability, and safety. Our ABB Switchgears are available in All India and can be exported to any location.

ABB Double Pole MCB /SB202M-C4

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):4 A Rated Operational Current (Ie):4 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:2 Number of Poles:2 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 1520 INR/Piece

ABB Single Pole MCB /SB201M-C50

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):240 / 415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):50 A Rated Operational Current (Ie):50 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:10000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:1 Number of Poles:1 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 740 INR/Piece

ABB Four Pole MCB /SB204M-C16

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):16 A Rated Operational Current (Ie):16 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:4 Number of Poles:4 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 2280 INR/Piece

ABB Single Pole MCB /SB201M-C25

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):240 / 415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):25 A Rated Operational Current (Ie):25 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:1 Number of Poles:1 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 370 INR/Piece

ABB Triple Pole MCB /SB203M-C40

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):40 A Rated Operational Current (Ie):40 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:10000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:3 Number of Poles:3 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 2700 INR/Piece

ABB Single Pole MCB /SB201M-C4

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):240 / 415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):4 A Rated Operational Current (Ie):4 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:1 Number of Poles:1 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 540 INR/Piece

ABB Single Pole MCB /SB201M-C6

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):240 / 415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):6 A Rated Operational Current (Ie):6 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:1 Number of Poles:1 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 370 INR/Piece

ABB Four Pole MCB /SB204M-C0.5

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):0.5 A Rated Operational Current (Ie):0.5 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:4 Number of Poles:4 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 3610 INR/Piece

ABB Triple Pole MCB /SB203M-C6

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):6 A Rated Operational Current (Ie):6 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:3 Number of Poles:3 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 1770 INR/Piece

ABB Double Pole MCB /SB202M-C32

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):32 A Rated Operational Current (Ie):32 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:10000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:2 Number of Poles:2 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 1080 INR/Piece

ABB Triple Pole MCB /SB203M-C1

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):1 A Rated Operational Current (Ie):1 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:3 Number of Poles:3 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 2580 INR/Piece

ABB Four Pole MCB /SB204M-C2

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):2 A Rated Operational Current (Ie):2 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:4 Number of Poles:4 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 3610 INR/Piece

ABB Four Pole MCB /SB204M-C10

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):10 A Rated Operational Current (Ie):10 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:4 Number of Poles:4 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 2280 INR/Piece

ABB Double Pole MCB /SB202M-C10

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):10 A Rated Operational Current (Ie):10 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:2 Number of Poles:2 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 1080 INR/Piece

ABB Double Pole MCB /SB202M-C1

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):1 A Rated Operational Current (Ie):1 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:2 Number of Poles:2 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 1670 INR/Piece

ABB Single Pole MCB /SB201M-C20

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):240 / 415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):20 A Rated Operational Current (Ie):20 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:1 Number of Poles:1 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 370 INR/Piece

ABB Overload Relay

ABB OLR-Overload Relay
Price: 800.00 - 1000.00 INR/Number

ABB Contactor

ABB Contactor
Price: 550 INR/Number

ABB Double Pole MCB /SB202M-C6

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):6 A Rated Operational Current (Ie):6 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:2 Number of Poles:2 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 1080 INR/Piece

ABB Single Pole MCB /SB201M-C63

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):240 / 415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):63 A Rated Operational Current (Ie):63 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:10000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:1 Number of Poles:1 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 740 INR/Piece

ABB Triple Pole MCB /SB203M-C50

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):50 A Rated Operational Current (Ie):50 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:10000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:3 Number of Poles:3 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 2700 INR/Piece

ABB Double Pole MCB /SB202M-C50

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):50 A Rated Operational Current (Ie):50 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:10000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:2 Number of Poles:2 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 1720 INR/Piece

ABB Four Pole MCB /SB204M-C4

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):4 A Rated Operational Current (Ie):4 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:4 Number of Poles:4 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 3610 INR/Piece

ABB fOUR Pole MCB /SB204M-C32

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):32 A Rated Operational Current (Ie):32 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:10000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:4 Number of Poles:4 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 2280 INR/Piece

ABB Triple Pole MCB /SB203M-C20

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):20 A Rated Operational Current (Ie):20 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:3 Number of Poles:3 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 1770 INR/Piece

ABB Single Pole MCB /SB201M-C16

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):240 / 415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):16 A Rated Operational Current (Ie):16 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:1 Number of Poles:1 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 370 INR/Piece

ABB Double Pole MCB /SB202M-C16

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):16 A Rated Operational Current (Ie):16 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:2 Number of Poles:2 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 1080 INR/Piece

ABB fOUR Pole MCB /SB204M-C50

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):50 A Rated Operational Current (Ie):50 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:10000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:4 Number of Poles:4 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 3490 INR/Piece

ABB MPCB

ABB MPCB - Motor Protection Circuit Breaker
Price: 2000.00 - 3000.00 INR/Number

ABB Triple Pole MCB /SB203M-C2

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):2 A Rated Operational Current (Ie):2 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:3 Number of Poles:3 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 2350 INR/Piece

ABB Double Pole MCB /SB202M-C40

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):40 A Rated Operational Current (Ie):40 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:10000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:2 Number of Poles:2 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 1720 INR/Piece

ABB Double Pole MCB /SB202M-C25

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):25 A Rated Operational Current (Ie):25 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:2 Number of Poles:2 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 1080 INR/Piece

ABB Triple Pole MCB /SB203M-C3

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):3 A Rated Operational Current (Ie):3 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:3 Number of Poles:3 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 2350 INR/Piece

ABB Four Pole MCB /SB204M-C25

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):25 A Rated Operational Current (Ie):25 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:4 Number of Poles:4 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 2280 INR/Piece

ABB Triple Pole MCB /SB203M-C0.5

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):0.5 A Rated Operational Current (Ie):0.5 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:3 Number of Poles:3 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 2580 INR/Piece

ABB Triple Pole MCB /SB203M-C1.6

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):16 A Rated Operational Current (Ie):16 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:3 Number of Poles:3 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 2580 INR/Piece

ABB Triple Pole MCB /SB203M-C4

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):4 A Rated Operational Current (Ie):4 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:3 Number of Poles:3 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 2350 INR/Piece

ABB Single Pole MCB 0.5A /SB201M-C0.5

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):240 / 415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):0.5 A Rated Operational Current (Ie):0.5 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:1 Number of Poles:1 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 620 INR/Piece

ABB Double Pole MCB /SB202M-C63

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):63 A Rated Operational Current (Ie):63 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:10000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:2 Number of Poles:2 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 1720 INR/Piece

ABB Triple Pole MCB /SB203M-C10

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):10 A Rated Operational Current (Ie):10 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:3 Number of Poles:3 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 1770 INR/Piece

ABB Double Pole MCB /SB202M-C1.6

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):1.6 A Rated Operational Current (Ie):1.6 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:2 Number of Poles:2 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 1670 INR/Piece

ABB Triple Pole MCB /SB203M-C25

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):25 A Rated Operational Current (Ie):25 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:3 Number of Poles:3 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 1770 INR/Piece

ABB Double Pole MCB /SB202M-C20

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):20 A Rated Operational Current (Ie):20 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:2 Number of Poles:2 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 1080 INR/Piece

ABB Double Pole MCB /SB202M-C0.5

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):0.5 A Rated Operational Current (Ie):0.5 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:2 Number of Poles:2 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 1670 INR/Piece

ABB fOUR Pole MCB /SB204M-C63

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):63 A Rated Operational Current (Ie):63 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:10000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:4 Number of Poles:4 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 3490 INR/Piece

ABB Double Pole MCB /SB202M-C3

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):2 A Rated Operational Current (Ie):2 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:2 Number of Poles:2 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 1520 INR/Piece

ABB Four Pole MCB /SB204M-C1

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):1 A Rated Operational Current (Ie):1 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:4 Number of Poles:4 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 3610 INR/Piece

ABB MCCB

ABB MCCB
Price: 4000.00 - 16000.00 INR/Number

ABB Single Pole MCB/SB201M-C1

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):240 / 415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):1 A Rated Operational Current (Ie):1 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:1 Number of Poles:1 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 620 INR/Piece

ABB Single Pole MCB/SB201M-C1.6

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):240 / 415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):1.6 A Rated Operational Current (Ie):1.6 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:1 Number of Poles:1 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 620 INR/Piece

ABB Single Pole MCB /SB201M-C2

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):240 / 415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):2 A Rated Operational Current (Ie):2 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:1 Number of Poles:1 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 540 INR/Piece

ABB Single Pole MCB /SB201M-C3

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):240 / 415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):2 A Rated Operational Current (Ie):2 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:1 Number of Poles:1 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 540 INR/Piece

ABB Single Pole MCB /SB201M-C10

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):240 / 415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):10 A Rated Operational Current (Ie):10 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:1 Number of Poles:1 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 370 INR/Piece

ABB Single Pole MCB /SB201M-C32

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):240 / 415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):32 A Rated Operational Current (Ie):32 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:10000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:1 Number of Poles:1 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 370 INR/Piece

ABB Single Pole MCB /SB201M-C40

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):240 / 415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):40 A Rated Operational Current (Ie):40 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:10000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:1 Number of Poles:1 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 740 INR/Piece

ABB Triple Pole MCB /SB203M-C16

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):16 A Rated Operational Current (Ie):16 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:3 Number of Poles:3 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 1770 INR/Piece

ABB Triple Pole MCB /SB203M-C32

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):32 A Rated Operational Current (Ie):32 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:10000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:3 Number of Poles:3 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 1770 INR/Piece

ABB Triple Pole MCB /SB203M-C63

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):63 A Rated Operational Current (Ie):63 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:10000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:3 Number of Poles:4 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 2700 INR/Piece

ABB Four Pole MCB /SB204M-C1.6

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):16 A Rated Operational Current (Ie):16 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:4 Number of Poles:4 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 3610 INR/Piece

ABB Four Pole MCB /SB204M-C3

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):3 A Rated Operational Current (Ie):3 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:4 Number of Poles:4 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 3610 INR/Piece

ABB Four Pole MCB /SB204M-C6

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):6 A Rated Operational Current (Ie):6 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:4 Number of Poles:4 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 2280 INR/Piece

ABB Four Pole MCB /SB204M-C20

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):20 A Rated Operational Current (Ie):20 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:20000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:4 Number of Poles:4 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 2280 INR/Piece

ABB fOUR Pole MCB /SB204M-C40

Standards:IS/IEC 60898-1 Tripping Characteristic:C Rated Voltage (Ur):415 V Operational Voltage:Maximum 264 V AC Maximum 60 V DC Rated Impulse Withstand Voltage (Uimp):4 kV Rated Current (In):40 A Rated Operational Current (Ie):40 A Rated Short-Circuit Capacity:10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Frequency (f):50 Hz Rated Frequency (f):50 Hz Energy Limiting Class:3 Electrical Endurance:10000AC cycle Mechanical Endurance:20000 cycle Number of Protected Poles:4 Number of Poles:4 Overvoltage Category:III Tightening Torque:2 N·m Actuator Type:Toggle Screw Terminal Type:Cage Terminal Actuator Marking:I / O Actuator Material:Insulation Group II, Black, Sealable Housing Material:Insulation Group II, RAL 7035 Mounting Position:Any Recommended Screw Driver:Pozidriv 2 Accessories Available:Yes Remarks:IP40 in enclosure with cover Connecting Capacity:rigid: 25 mm² ; flexible: 16 mm²
Price: 3490 INR/Piece

ABB MCB

Price: 220 INR/Unit
X